Wait Field Text
UiPath.Terminal.Activities.TerminalWaitFieldText
Description
Waits for a specified amount of time for a String to appear in a
form field.
The activity is valid only inside a Terminal Session activity.
note
This activity fails if the VT family of terminals is being used, either with the Direct Connection provider or with a provider using a 3rd party terminal emulator, like IBM EHLLAPI. This happens because the VT family of terminals does not support fields.
Project compatibility
Windows - Legacy | Windows
Configuration
Designer panel
- LabeledBy - The label that appears before the field to be searched for.
- Index - If there are multiple fields with the same labels, select an identifier greater than 0 that describes the order of the label to be searched for.
- FollowedBy - The label that appears after the field to be searched for.
- Text - The
Stringto be waited for.
Properties panel
Common
- DisplayName - The display name of the activity.
Field
- FollowedBy - The label that appears after the field to be searched for.
- Index - If there are multiple fields with the same labels, select an identifier greater than 0 that describes the order of the label to be searched for.
- LabeledBy - The label that appears before the field to be searched for.
Input
- MatchCase - Specifies if the text matching should be case sensitive. Only boolean values (True, False) are supported.
- Text - The
Stringto be waited for.
Misc
- Private - If selected, the values of variables and arguments are no longer logged at Verbose level.
Options
- DelayMS - Delay time (in milliseconds) after executing the activity. The default amount of time is 300 milliseconds (0.3 seconds).
- TimeoutMS - Specifies the amount of time (in milliseconds) to wait for the activity to run before an error is thrown. The default value is 5000 milliseconds (5 seconds).
- WaitType - Before
performing the actions, wait for the target to become ready. The following
options are available:
- NONE - Does not wait for the terminal keyboard to be enabled.